Assign IP addresses to devices on an EtherNet/IP network using rotary switches and a variety of software.Configure a Stratix® switch (5700, 8000, and/or 8300) to meet a variety of network requirements.This course should prepare you to effectively: Note: If all of the fields are “Grayed out”, be sure you selected “Static”.Ethernet/IP Configuration and Troubleshooting Course Purpose The IP should be scrolling across the alphanumeric display. Be sure to hit “Apply” then “OK”, then look at your module in the chassis. Here, you can assign the IP address of your replacement module with the information we gathered in Step 1. Next, click on the “Port Configuration” tab: Once you find your Ethernet module, right-click the module, and choose “Module Configuration”. You will see the Ethernet module that you need to configure. Once you have communication with a module in the chassis, you can drill through the module to the backplane. Step 2: Find the Ethernet module in RSWho Then replace the module, and follow steps 2 and 3 again to assign the information to the NEW module. Another method would be to follow steps 2 and 3 below to read the information off the OLD module. If you are unsure of what your plant uses, consult your plant standards, or system administrator. Then, the gateway, DNS, and host are left blank. The most common configuration is a subnet mask of 255.255.255.0. You will also need to know the subnet mask, and any other information that needs to be entered, such as a gateway, and DNS servers. The properties screen should display the information you need to assign the IP address. Next, right-click on the Ethernet module that you are replacing, and go to “properties”.


If the project is documented properly, you can open the offline file. Another way to get the IP address to use for a replacement module is in Studio 5000. You might have a spreadsheet in your plant that lists all the IP addresses. If it is totally dead, we will have to refer to other documentation. If the old module still powers up, the IP address of the old module should scroll across the front. Step 1: Determine what the IP address of the new module should be.ĭo not guess at what the IP address should be of a replacement module. Another communication path would be through a USB port, or through the DF1 Driver. You can use an Ethernet driver if there is another Ethernet module in the chassis. When you are Assigning IP Address with RSLinx, you must have communication to at least one other module in the chassis. FactoryTalk View SE Trends and Data Log.Beginning a FactoryTalk View SE Project.Derivative Settings for ControlLogix PID Enhanced.Integral Settings for ControlLogix PID Enhanced.Proportional Settings for ControlLogix PID Enhanced (PIDE).Proportional, Integral, Derivative (PID).